ACCESS
CONTROL - IMPROX MMA
 |
Download pdf format
(contains detailed information) |
ImproX Mullion Antenna Reader
INTRODUCTION
The ImproX (MMA) Mullion Antenna Reader
is a compact Reader. The Antenna Reader includes a Status
LED; its functions are application specific.
The MMA is designed for exclusive use with
an ImproX TT Twin Antenna Terminal in the ImproX IXP200,
300 and 400 Access Control Systems.
The Antenna Reader is intended for indoor
or outdoor use. The electronic components are potted enhancing
its resistance to tampering.
APPLICATIONS
The following are possible uses of the Antenna
Reader: Access control Antenna Reader.
FEATURES
The ImproX MMA provides the following features:
- A single bi-coloured red/green Status LED.
- Read/Write tag capability for various tag types: Slim
Tags (Read Only), Omega Tags (Read Only), WriTag 128 (Read/Write)
and WriTag 2048 (Read/Write).
TAG READING RANGES
The range that the ImproX MMA Antenna Reader
can read from or write to a tag is dependent on:
- The type of tag being read.
- The material on which the ImproX MMA has been installed.
Typical ranges are shown in Table 1.
ACCESSORIES
The ImproX MMA is supplied with the following
accessory:
- 8 m (26.24 ft) of 4-core, 0.5 mm (0.01 in) Solid Strand
Communications Cable.
INTERNATIONAL STANDARDS
The ImproX MMA Antenna Reader complies with
requirements of the following international standards where
applicable (tests applicable only when the Antenna Reader
is connected to an ImproX TT Twin Antenna Terminal).
- EN 55024
Limits and Methods of Measurement of Radio Disturbance Characteristics
of Information Technology Equipment.
- EN 61000-6-1 Generic Standards-Immunity.
- EN 61000-6-3 Generic Standards-Emission.
- EN 61000-4-1 Electromagnetic Compatibility (EMC). Part
4: Testing and Measurement Techniques. Section 1: Overview
of Immunity Tests. Basic EMC Publication.
- EN 61000-4-2 Electromagnetic Compatibility (EMC). Part
4: Testing and Measurement Techniques. Section 2: Electrostatic
Discharge Immunity Test. Basic EMC Publication.
- EN 61000-4-4 Electromagnetic Compatibility (EMC). Part
4: Testing and Measurement Techniques. Section 4: Electrical
Fast Transients / Bursts. Basic EMC Publication.
- EN 61000-4-3 Electromagnetic Compatibility (EMC). Part
4: Testing and Measurement Techniques. Section 3: Radiated,
Radio-Frequency, Electromagnetic Field Immunity Test.
- EN 61000-4-6 Conducted Susceptibility.
- EN 61000-4-5 Surge Immunity.
APPROVALS
CE Approval: Approved.
TAMPER PROOFING
The Antenna Reader is potted, and is therefore
tamper-resistant.
RELATED IMPRO PRODUCTS
The ImproX MMA Antenna Reader is designed
to be used with the ImproX (TT) Twin Antenna Terminal.
ORDERING INFORMATION
The ImproX MMA Antenna Reader can be ordered
separately under the Impro code XTT901-1-0-GB-XX.
APPLICABILITY OF THIS CATALOGUE
The last two digits of the standard Impro
stock code indicate the issue status of the item concerned.
This catalogue is applicable to the ImproX (MMA) Mullion
Antenna Reader, XTT901-1-0-GB-00.
|